2024 Pentair easy touch troubleshooting - Jan 25, 2021 · From https://www.justanswer.com/ythiJustAnswer Customer: I have a pentair easy touch that is reading "no comm" after power went out to house during storm.Jus...

 
About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright .... Pentair easy touch troubleshooting

Water Softening & Filtration Products. Warranty Information. Still have questions? We've got you. Contact Us. If you're feeling alone in the management of your residential pool, just know that Pentair is here to help you out. Don't miss out on our support!I have a Pentair EasyTouch 8. The remote will no longer communicate (address won't lock and tried all the troubleshooting stuff). I've decided it's time to modernize and control my pool with my smart phone and Alexa. I'm looking at the screenlogic 2 kit, but I'm having a tough time deciphering how it connects. It seems you …IntelliBrite LED lights are fully compatible with Pentair IntelliTouch® and EasyTouch ... Use the following tips to help to resolve problems that might occur while operating the IntelliBrite Controller. Both of the LEDs are flashing. The IntelliBrite Controller has detected that the load has exceeded the maximum allowable wattage or the output is shorted out 1. Switch …With SunTouch, your pump and heater automatically run whenever you want, for as long as you want, so your pool and spa are always warm and inviting. Or, switch to manual mode for those spontaneous plunges. Either way, you’re in complete control. One-touch function—no complicated routine to memorize. Ability to program pool and spa and 2 ...iii EasyTouch ®, IntelliTouch Control System Load Center Installation Guide EasyTouch® ® Control System Load Center Installation Guide This product is designed and manufactured for safe and reliable service when installed, operated and maintained according to the information and installation codes referred to in this Guide.or EasyTouch® Control System Load Center and connect the four-wire cable to the COM port connector located in the IntelliTouch or EasyTouch Control System Load Center: Mount the Transceiver Module The Transceiver is a two-way radio device with an attached antenna that communicates to and from the IntelliTouch or EasyTouch Control System. Perform your own maintenance by following a few simple steps, and you will save yourself frustration, time, and money. You can examine the power connection to your LX Control …Oct 25, 2017 · If you have something else on the buss, like ScreenLogic or a SWG and they work, then the problem will not be the EasyTouch's communications buss. So, step one is to ensure the date cable is connected at the pump and inside the EasyTouch. Step two is to see if the pump's display reads "Display not Active." EasyTouch® Wireless Setup 1. From EasyTouch control panel press Menu. 2. Press Down button - Select "SETTINGS". 3. Press Right button. 4. Press Up button up to "Wireless Address". 5. Press Right button to select. "Address Wireless scanning" is displayed. Then "Sending Address” will display. 6. Repeat steps 1-5 from wireless handheld. "AddressPage 66: Section 3 - Troubleshooting (such as circuits with freeze protection, etc.). The second relay switches the pump from low speed to high speed. The default condition is low speed. Up to seven circuits …There are two EasyTouch system configurations available; EasyTouch 8 (auxiliary circuits) and EasyTouch 4 (auxiliary circuits). The EasyTouch system is factory configured to …Jun 3, 2018. #1. All - I'm having a problem with the colors on my Pentair lights in my pool. Some details are below: 1: My pool was completed as an owner-builder pool in July 2017, just under 1 year ago. 2: I have 1 Pentair Intellibrite 5G color LED light, and also 3 Pentaid color LED globrites installed. 3: The pool and lighting is controlled ...Pentair Water Pool and Spa, Inc. (“Pentair”) does not represent or otherwise guarantee that the proper use of the (SCG) will prevent corrosion or other deterioration of pool equipment and any surfaces used in and around your pool. Consult your experienced pool professional, who should be able to advise you on the proper material EasyTouch System. Indoor Control Panel (4- or 8-Function Control) EasyTouch System. Wireless Controller. iS4. 4-Function . Spa-Side Remote. SpaCommand® Spa-Side Remote. 10-Function Spa-Side Remote *The Pentair ScreenLogic Interface for MACINTOSH® DESKTOP COMPUTERS IS NOT COMPATIBLE with the recently released 64-bit-speed Macintosh CATALINA ... Remotely manage from a Mac® Computer or PC using the ScreenLogic2 Interface application. Easily change, track and monitor history of pH and ORP levels when using the IntelliChem® Water Chemistry Controller with IntelliTouch® or EasyTouch® automation systems. ScreenLogic2 app now allows full-color lighting control for both IntelliBrite® LED ...Nov 26, 2018 · Nov 26, 2018. #1. Moved from here. I too have a Pentair Easy Touch system and an IC40 that was installed just this past June. It had been working fine and registering the PPM, but now for some reason the Chlorinator diagnostics on the Easy Touch is indicating 0 PPM. The systems says there are no errors and all the lights are green on the IC40 ... 1. From EasyTouch control panel press Menu. 2.Press Down button - Select “SETTINGS”. 3.Press Right button. 4.Press Up button up to “Wireless Address”. 5.Press Right button to select. “Address Wireless scanning” is displayed. Then “Sending Address” will display. 6. 6.Repeat steps 1-5 from wireless handheld. “Address Found” The EasyTouch Control System eliminates the inconvenience of trips to your pool equipment pad, memorizing operating sequences, opening and closing valves and resetting time clocks and thermostats.Jun 5, 2021 · I have a Pentair Easytouch (8) control system with the Easytouch Wireless Remote that is not connecting to the control panel and reading 'No Comm'. It started to loose connection with the panel last weekend. I was able to reconnect the remote two times by doing the following: - Power down the control panel at the main breaker and then power back up Pentair EasyTouch 8 Installation Manual (32 pages) Pool and Spa Control System (with optional IntelliChlor Electronic Chlorine Generator) Brand: Pentair | Category: Control Systems | Size: 2.88 MB. Table of Contents.It requires sophisticated electrical troubleshooting equipment to diagnose, so it is recommended to have a qualified professional out to diagnose as the tools to purchase, even if you learned how to use them effectively, would likely cost the same or more than the repair would.There are two EasyTouch control system configurations available; EasyTouch 8 (auxiliary circuits) and EasyTouch 4 (auxiliary circuits). The EasyTouch control system is factory configured to operate with a “shared” equipment system or with a “single body” system. iii EasyTouch ®, IntelliTouch Control System Load Center Installation Guide EasyTouch® ® Control System Load Center Installation Guide This product is designed and manufactured for safe and reliable service when installed, operated and maintained according to the information and installation codes referred to in this Guide.It requires sophisticated electrical troubleshooting equipment to diagnose, so it is recommended to have a qualified professional out to diagnose as the tools to purchase, even if you learned how to use them effectively, would likely cost the same or more than the repair would.IMPORTANT WARNING AND SAFETY INSTRUCTIONS Important Notice: Attention Installer: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment. I have a Pentair MasterTemp 250 Spa heater and Easy Touch Control System. Spa control does not come on (no lights on pad) when tough Spa on. I have run through a few items to check. House Breakers on … read more When it comes to programming in C, having a C compiler is essential. However, installing a C compiler can sometimes be a challenge. In this article, we will discuss how to troubleshoot installation issues when installing a C compiler.The EasyTouch control system menu features let you create customized schedules for your pool and spa equipment, heat temperatures, and chlorination settings to switch on and off at a set day and time. Page 11 10 minutes to allow the heater to cool down. Pentair heaters do not require a cool down time.If you are looking for the installation guide for the EasyTouch PL4 or PSL4 pool and spa control systems, you can download the PDF file from this link. This guide will help you to install and configure the control system, the wireless controller, and the ScreenLogic interface. You will also find troubleshooting tips and safety instructions.! " # $%& 2 -1 9 -0 4 / ( )* +,--.' - . ) ! /0 1 &/; 2 4 0 < . : &) . 1 ! . : w a r n in g r is k o f e l e c t r ic a l s h o c k o r e l e c t r o c u t io nWEBSITE: http://www.swimmingpoollearning.com/YouTube Video Index – A list of all of my videos:http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-revi...Carrier thermostats can be troubleshooted by looking for common problems and addressing these problems one at a time until the problem is fixed. Some common problems may include a system that is not heating or cooling enough or a system tha...View and Download Pentair EasyTouch 8 and 4 installation manual online. Pool and Spa Control System (with optional IntelliChlor Electronic Chlorine Generator). EasyTouch 8 …When your printer is offline, it can be a frustrating experience. It can be difficult to figure out what the problem is and how to fix it. Fortunately, there are some simple steps you can take to troubleshoot the issue and get your printer ...The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of the pool water and solar collectors. SolarTouch Control System integrates with IntelliFlo and IntelliPro Variable Speed pumps for …Product owners manuals are available for nearly every product to help you and your pool professional install and service your pool and spa equipment and accessories. The manuals and guides are organized by equipment category. Select the category of interest to view a list of available owners manuals. For additional product information, please ...This video is a quick tip guide to making sure your Pentair Screenlogic 2 Transmitter or Screenlogic 2 antenna is working at it’s optimum. We’ll give a few t...A systematic approach to solving the problem is often the best way to track down and then correct engine problem, according to Kohler Power. The first step of troubleshooting to figure out what’s wrong with a Kohler engine is identifying th...Now, you can make it even more convenient to run your pool, spa or combination with the added ease of a wired or wireless remote. Plus, you can program your equipment for optimal energy efficiency. Allows easy upgrade to EasyTouch® Automation functionality for the following Compool® Systems: CP3400, CP3600, CP3800, CP3810, CP1000*, CP2000 ... Consult Pentair Water Pool and Spa, Inc. with any questions regarding this product. This product is intended for use in swimming pool applications only. ... EasyTouch Wireless Control Panel, 8 circuits (P/N 520547) iS4 Four-Function Spa-Side remote, 150 ft. cable (P/N 520094)Product owners manuals are available for nearly every product to help you and your pool professional install and service your pool and spa equipment and accessories. The manuals and guides are organized by equipment category. Select the category of interest to view a list of available owners manuals. For additional product information, please ...Apr 12, 2023 · We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out the input/outputs on my board. This is an E... I have a Pentair MasterTemp 250 Spa heater and Easy Touch Control System. Spa control does not come on (no lights on pad) when tough Spa on. I have run through a few items to check. House Breakers on … read more Jan 25, 2021 · From https://www.justanswer.com/ythiJustAnswer Customer: I have a pentair easy touch that is reading "no comm" after power went out to house during storm.Jus... an Intelliflo pump won't run the schedule. screenlogic can't control the system. communication timeout errors show on the intellitouch indoor panel. an Easytouch …Page 66: Section 3 - Troubleshooting (such as circuits with freeze protection, etc.). The second relay switches the pump from low speed to high speed. The default condition is low speed. Up to seven circuits …Sep 11, 2020. #5. The ET should not have powered down in Service mode. Check the breakers in the ET panel. Check the pump display to see if the pump has power. @Jimrahbe will chime in when he comes online. Report.About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Wondering if anyone has a comprehensive list of the self-test/diagnostic fail codes by an EasyTouch. IODIN got one 146 a few date formerly, when my IntelliChlor …Yellow iron is a vital piece of equipment for many industries, and when it malfunctions, it can have a major impact on productivity. Fortunately, there are some common issues that can be easily addressed with a few simple troubleshooting st...Share. 2.7K views 6 months ago #pentair #easytouch. We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out communications with the pump ...Troubleshooting Pentair Ultratemp temperature reading. My Ultratemp had been working just fine upon opening of the pool, but I didn't notice it running this last week. We hadn't been in the pool, so no big deal. When I opened the cover on Sunday to swim with my son, the water was nowhere near the 86 degree setting on the heat pump.Are you having trouble with your Maytag washer? Don’t worry, you’re not alone. Many people have experienced issues with their Maytag washers, and it can be difficult to know where to start when it comes to troubleshooting.Consult Pentair Water Pool and Spa, Inc. with any questions regarding this product. This product is intended for use in swimming pool applications only. ... EasyTouch Wireless Control Panel, 8 circuits (P/N 520547) iS4 Four-Function Spa-Side remote, 150 ft. …Wondering if anyone has a comprehensive list of the self-test/diagnostic fail codes by an EasyTouch. IODIN got one 146 a few date formerly, when my IntelliChlor …1. Oct 26, 2013. #9. Re: Pentair Easy Touch 4 remote not working after pool openi. One thing that you can also do is to turn off all your led lights. After replacing my old light bulbs with led bulbs, I have noticed that the led bulbs produce electrical interference and can cause a lack of communication. I hope this helps.SolarTouch® Solar Control System Installation and User’s Guide ® SolarTouch Solar Control System Installation and User’s Guide To reduce the risk of injury, do not permit children to use this product. However, occasionally, you can encounter some problems, and troubleshooting may seem daunting, without the help of a professional. But you can manage well if you tweak around in a set pattern. ... Pentair GloBrite Problems- Top 10 Issues and Complaints; Polaris Tail Not Moving/Sweeping (For Model 3900, 280, 360, 380) Polaris 380 Wheels …When your printer is offline, it can be a frustrating experience. It can be difficult to figure out what the problem is and how to fix it. Fortunately, there are some simple steps you can take to troubleshoot the issue and get your printer ...Auto. Pool (or Spa) 85*F. Air 81*F. Fri - 05:46 PM. If the above is ok, I would reload the protocol adapter and then download the PC program again. At this point I would only worry about getting ScreenLogic working via your PC. Once it works, than worry about the phone. Use this Pentair site... ScreenLogic Update.Remotely manage from a Mac® Computer or PC using the ScreenLogic2 Interface application. Easily change, track and monitor history of pH and ORP levels when using the IntelliChem® Water Chemistry Controller with IntelliTouch® or EasyTouch® automation systems. ScreenLogic2 app now allows full-color lighting control for both IntelliBrite® LED ...Share. 2.7K views 6 months ago #pentair #easytouch. We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out communications with the pump ...Wondering if anyone has a comprehensive list of the self-test/diagnostic fail codes by an EasyTouch. IODIN got one 146 a few date formerly, when my IntelliChlor …To install a relay: 1. Install optional auxiliary relays below the pre-installed relays. Secure in place with two retaining screws. Depending on the EasyTouch model, there may be up to 5 available relay positions (EasyTouch 8 includes eight relays and …Jun 7, 2017 · The LCD is replaceable if you can solder / desolder. The part is available for $5-15. I couldn't find the exact LCD so I found a compatible part but the screen was blue with white text (nice upgrade): Manufacturer: Winstar Part Number: WH1604A-TMI-JT. Original part was EW16400GLY from Emerging Displays. Now incorporating built in electrical outlets for lower cost installation. PNP 10 unit includes 10 outlets - 8 Auxiliaries plus 2x 15A permanent power. PNP 5 unit includes 5 outlets - 4 Auxiliaries plus 1x 15A permanent power. Certified to Australian Standards. Dimensions: 26 in. H x 17 in. W x 5-1/4 in. D.If you have questions about ordering Pentair replacement parts, and pool products, please use the following contact information: CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service (8 A.M. to 4:30 P.M. — Eastern and Pacific Times) Phone: (800) 831-7133 Fax: (800) 284-4151 Web site Visit www.pentair.com for more information about …Jun 21, 2016 · Jun 21, 2016. #1. We have a Pentair EasyTouch 8 control system for our in-ground pool and this past weekend, following a fairly severe electrical storm, neither the filter nor cleaner pump was working. When I went to investigate I found that the only apparent problem was that the low voltage circuit breaker that is labeled "Relays" was open. A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3® VSF Pool Pump leverages built-in sensorless flow control for optimum water flow and adjusts to pool conditions, keeping pools performing at their best. Set up, monitor and operate the pump from anywhere with wireless technology control through the ...1. From EasyTouch control panel press Menu. 2.Press Down button - Select “SETTINGS”. 3.Press Right button. 4.Press Up button up to “Wireless Address”. 5.Press Right button to select. “Address Wireless scanning” is displayed. Then “Sending Address” will display. 6. 6.Repeat steps 1-5 from wireless handheld. “Address Found” 1. Make sure your wireless ScreenLogic2 device is connected to your wireless router. In most cases, theeasiest way to re-establish a connection is to perform a cold boot of the ScreenLogic2 device: a. Wireless Tablet – Press the Suspend button located on the left-side of the Tablet for approximately 4seconds.Pentair Pool Filters, Pool Pumps, Pool Heaters, Pool Lighting & Pool Automation Call Us: 1-800-831-7133WEBSITE: http://www.swimmingpoollearning.com/YouTube Video Index – A list of all of my videos:http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-revi...I have a Pentair MasterTemp 250 Spa heater and Easy Touch Control System. Spa control does not come on (no lights on pad) when tough Spa on. I have run through a few items to check. House Breakers on … read more INFORMATION AT YOUR FINGERTIPS. Stay smart, connected and protected with the Pentair Home app. This product is one of a range of connected products from Pentair that gives you command of your home's water. From filter to flow, tap to pool, shower to sump pump, we help you move, improve and enjoy your water, with peace of mind at your fingertips.EasyTouch® or IntelliTouch® Automation System control panel will resume the next time the spa mode is activated using the “Set manual heat” function (see the EasyTouch automation User’s Guide (P/N 520584) and IntelliTouch automation User’s Guide (P/N 521075) for details. The “Spa” mode will automatically switch off after 24 hours.Nov 5, 2012 · Posted November 5, 2012. Pool equipment was running on automated settings via Easy Touch control panel. Equipment stopped working. Switched to service mode to operate equipment manually and the main pump and booster pump won't turn on, but the falls pump will turn on manually. Quote. Carrier thermostats can be troubleshooted by looking for common problems and addressing these problems one at a time until the problem is fixed. Some common problems may include a system that is not heating or cooling enough or a system tha...We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out the input/outputs on my board. This is an …If your fridge isn’t keeping your food cold, it can be a hassle to figure out what’s wrong. Fortunately, there are some simple steps you can take to troubleshoot the problem and get your fridge back up and running. Here’s an easy guide to t...Pentair easy touch troubleshooting

EasyTouch® or IntelliTouch® Automation System control panel will resume the next time the spa mode is activated using the “Set manual heat” function (see the EasyTouch automation User’s Guide (P/N 520584) and IntelliTouch automation User’s Guide (P/N 521075) for details. The “Spa” mode will automatically switch off after 24 hours.. Pentair easy touch troubleshooting

pentair easy touch troubleshooting

Pool Automation that is Simple and Affordable. The EasyTouch Control System eliminates the inconvenience of trips to your pool equipment pad, memorizing operating sequences, opening and closing valves and resetting time clocks and thermostats. With push-button operation and clear, intuitive instructions and displays, your EasyTouch system ...If you are experiencing any issues with your Pentair Easy Touch, the first step to take is to troubleshoot it. Before attempting any repairs, check for common problems such as power interruptions or water pressure changes.I have a Pentair MasterTemp 250 Spa heater and Easy Touch Control System. Spa control does not come on (no lights on pad) when tough Spa on. I have run through a few items to check. House Breakers on … read more The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of the pool water and solar collectors. SolarTouch Control System integrates with IntelliFlo and IntelliPro Variable Speed pumps for …I have a Pentair MasterTemp 250 Spa heater and Easy Touch Control System. Spa control does not come on (no lights on pad) when tough Spa on. I have run through a few items to check. House Breakers on … read moreIf your fridge isn’t keeping your food cold, it can be a hassle to figure out what’s wrong. Fortunately, there are some simple steps you can take to troubleshoot the problem and get your fridge back up and running. Here’s an easy guide to t...This video will help if your salt cell appears to have no power (all lights out). Try this if your power box does NOT have a glass fuse, but a mini blade fuse.Apr 19, 2022 · I have Pentair EasyTouch control system with IntelliPH acid dispenser and Intellichlor IC40 SWG. I recently performed a pump head tube replacement on the IntelliPH. Shortly after doing so I noticed no power to my IC40. Upon further review I noticed the 12amp Intellichlor breaker was tripped. I reset and 10-20 minutes later it trips. The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of the pool water and solar collectors. SolarTouch Control System integrates with IntelliFlo and IntelliPro Variable Speed pumps for …SolarTouch® Solar Control System Installation and User’s Guide ® SolarTouch Solar Control System Installation and User’s Guide Introduction The SolarTouch® Solar Controller system consists of a four button controller, a valve actuator, a positive sealed diverter valve and two temperature sensors (used for water and solar). SolarTouch solar controller …iii EasyTouch ®, IntelliTouch Control System Load Center Installation Guide EasyTouch® ® Control System Load Center Installation Guide This product is designed and …Pentair Intellichlor IC-60. Mar 1, 2017. #5. Check the antenna that connects to the main panel. Make sure all the connections are solid. The antennae (both for ScreenLogic and the RF remote....looking at you Jim!!) are susceptible to getting fried by power surges and what not. You might need to replace it.assumes that all system equipment has been properly installed and connected to the EasyTouch Load center. Testing Valve Actuators and Pumps: Use the following steps to test the valve actuators (CVA24T) for proper rotation. To test the valve actuators and pump: 1. Switch on the electrical power at the house breaker. 2. Switch on …Pentair Easy Touch Troubleshooting . If you are experiencing any issues with your Pentair Easy Touch, the first step to take is to troubleshoot it. Before attempting any repairs, check for common problems such as power interruptions or water pressure changes. If these checks don’t resolve the issue, consult your user manual and follow its …A repository of Pentair stakeholder and customer information at your fingertips including white papers, case studies and product manuals, etc. View our downloads here. For example, if we set the spa temperature to 100F on our remote and turn the heater on, the heater will turn on but it won't heat to the temperature we have set on the remote unless we physically go to the heater and adjust the temperature manually on the heater display itself. Same for adjusting the heat temperature when heating the pool.Jul 7, 2017 · Pentair Easy Touch with Remote. I am new home owner and the remote was working, now intermittently works. I tried Reset for panel and remote, also your 4/24/2015 re Wireless Address. Remote says 'Addr … read more EasyTouch ®, IntelliTouch Control System Load Center Installation Guide Water temperature in excess of 100° F (37.7° C) may be hazardous to your health. Prolonged immersion in hot water may induce hyperthermia. INFORMATION AT YOUR FINGERTIPS. Stay smart, connected and protected with the Pentair Home app. This product is one of a range of connected products from Pentair that gives you command of your …1. From EasyTouch control panel press Menu. 2.Press Down button - Select “SETTINGS”. 3.Press Right button. 4.Press Up button up to “Wireless Address”. 5.Press Right button to select. “Address Wireless scanning” is displayed. Then “Sending Address” will display. 6. 6.Repeat steps 1-5 from wireless handheld. “Address Found” February 09, 2020 Communication issues are among the most common problems people run into with their Pentair pool equipment. The following problems can be caused by faulty communication: pressing a button on a remote or indoor controller does nothing an Intelliflo pump won't run the schedule screenlogic can't control the systemor EasyTouch® Control System Load Center and connect the four-wire cable to the COM port connector located in the IntelliTouch or EasyTouch Control System Load Center: Mount the Transceiver Module The Transceiver is a two-way radio device with an attached antenna that communicates to and from the IntelliTouch or EasyTouch Control System.There are two EasyTouch system configurations available; EasyTouch 8 (auxiliary circuits) and EasyTouch 4 (auxiliary circuits). The EasyTouch system is factory configured to …When your printer is offline, it can be a frustrating experience. It can be difficult to figure out what the problem is and how to fix it. Fortunately, there are some simple steps you can take to troubleshoot the issue and get your printer ...When your Maytag refrigerator isn’t cooling, it can be a major inconvenience. Fortunately, there are a few troubleshooting tips that you can try to get your refrigerator back up and running. Here are some steps you can take to get your Mayt...However, occasionally, you can encounter some problems, and troubleshooting may seem daunting, without the help of a professional. But you can manage well if you tweak around in a set pattern. The sooner you find the cause, the quicker you can deal with the problem. Here’s what to do if your Screenlogic refuses to connect locally or remotely: ...† FAQs and Troubleshooting (page 67): Frequently asked questions about using ScreenLogic2 interface. Also includes troubleshooting information. † Glossary (page 71): Glossary of terms used in this manual. Technical Support Sanford, North Carolina (8 A.M. to 5 P.M.) Moorpark, California (8 A.M. to 5 P.M.) Phone: (800) 831-7133 Fax: (800) 284 ...We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out communications with the pump and ScreenLogi...INTELLICHEM ® Water Chemistry Controller Installation and User s Guide ii IMPORTANT WARNING AND SAFETY INSTRUCTIONS WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling intoPentair EasyTouch PL4 Control System with ScreenLogic for Pool or Spa Only 522353. 0 reviews / Write a review. Available in Store. Call 909-595-5744 or email [email protected] for more details. Product Code: 522353.WEBSITE: http://www.swimmingpoollearning.com/YouTube Video Index – A list of all of my videos:http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-revi...Nov 26, 2018 · Nov 26, 2018. #1. Moved from here. I too have a Pentair Easy Touch system and an IC40 that was installed just this past June. It had been working fine and registering the PPM, but now for some reason the Chlorinator diagnostics on the Easy Touch is indicating 0 PPM. The systems says there are no errors and all the lights are green on the IC40 ... Actually an IntelliCenter i8PS with IC-40 is ~$2,900 and an EasyTouch 8 with IC-40 is ~$1,900. However you will spend another $700 for the EasyTouch for ScreenLogic. The price difference is not that great and the updates can be loaded by you. There is really little reason to consider IntelliTouch these days. Report.Jun 16, 2020 · Go out to the outside control unit, and with the pump running, and in the pool mode Auto, push the Aux 3 button.. Your Intake valve should stay in the pool mode and the Return valve should rotate to the Spa mode. >>> IT WORKS!!!! one of the valve changed position and the spa jets were working. We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out communications with the pump and ScreenLogi...Troubleshooting Pentair Ultratemp temperature reading. My Ultratemp had been working just fine upon opening of the pool, but I didn't notice it running this last week. We hadn't been in the pool, so no big deal. When I opened the cover on Sunday to swim with my son, the water was nowhere near the 86 degree setting on the heat pump.Pentair Pool Filters, Pool Pumps, Pool Heaters, Pool Lighting & Pool Automation Call Us: 1-800-831-7133Pentair Easy Touch Troubleshooting . If you are experiencing any issues with your Pentair Easy Touch, the first step to take is to troubleshoot it. Before attempting any repairs, check for common problems such as power interruptions or water pressure changes. If these checks don’t resolve the issue, consult your user manual and follow its …Having trouble with your Amazon Echo device? Don’t worry, you’re not alone. Many people have difficulty setting up and troubleshooting their Alexa devices. Here are some tips and tricks to help you get your device up and running in no time.1. With the power off I would disconnect ScreenLogic from the EasyTouch's com port. Disconnect the SWCG by unplugging the cable at the EasyTouch. Disconnect the pump from the EasyTouch by unplugging the cable at the pump. 2. Turn the power on to the pump and test the pump to make sure it responds to commands from the pump's …Are you having trouble logging into your Fitbit account? Don’t worry, you’re not alone. Many users encounter login issues from time to time. In this article, we will provide you with some troubleshooting tips to help you get back into your ...Water Pool and Spa, Inc. (“Pentair”) with any questions regarding this product. This product is intended for use in swimming pool applications only. Most states and local codes regulate the construction, installation, and operation of pub- ... EASYTOUCH® PL4/PSL4 Control Systems Power Center Installation Guide EasyTouch ...Learn how to install the EasyTouch Pool and Spa Control System Load Center with this comprehensive and detailed guide. This PDF document covers the installation steps, …Place the EasyTouch control panel face down on a flat clean surface. Remove the six screws securing the battery cover. Set the cover aside. Screw (6x) Battery cover Easy Touch Control Panel (rear view) EasyTouch Wireless Control Panel Installation and User’s Guide f8 Installing batteries (Continued) 2.The lockscrew is located at the 12 o’clock position on the light fixture face. If the fixture wobbles when touched or a strong ripple hits it then a loose screw is likely the cause. To fix the issue, dip into your pool with a phillips head screwdriver and tighten the screw. If the screw is stripped or lost, make sure you replace the screw and ...With four different configurations available, there’s an EasyTouch system to fit every pool and spa. The EasyTouch PL4 control system is a four-circuit system designed for a single body of water, while the EasyTouch PSL4 system is a four-circuit system designed to control a pool/spa combination. For even greater control, add an optional Pentair Pool Filters, Pool Pumps, Pool Heaters, Pool Lighting & Pool Automation Call Us: 1-800-831-7133 Pentair EasyTouch 8 Installation Manual (32 pages) Pool and Spa Control System (with optional IntelliChlor Electronic Chlorine Generator) Brand: Pentair | Category: Control Systems | Size: 2.88 MB. Table of Contents.Pumps, chlorine generator, etc are all Pentair. Pool is 6 years old. Everything is working normally after the recent power outage except the remote, which displays "NO COMM". I tried resetting the system from the outdoor control panel. When that didn't work, I shut off power to the outdoor control panel to reset it that way. Nope.These GFCI breakers are the right choice in load centers supporting IntelliTouch® and EasyTouch® Control Systems. Added safety of 6 milliamp personnel protection. Meets 2008 to current NEC standards for pool pumps. Designed to protect personnel exposed to ground fault in AC, DC and mixed AC/DC systems where levels exceed 6 milliamps.Jun 3, 2018 · Jun 3, 2018. #1. All - I'm having a problem with the colors on my Pentair lights in my pool. Some details are below: 1: My pool was completed as an owner-builder pool in July 2017, just under 1 year ago. 2: I have 1 Pentair Intellibrite 5G color LED light, and also 3 Pentaid color LED globrites installed. 3: The pool and lighting is controlled ... Sump Pump Troubleshooting FAQ. Go Back. Utility Pump Info FAQ. Go Back. Pentair WellMate FAQs. Go Back. Our Impact. Go Back. Our Impact. Go Back. Project Safewater. Go Back. ... EasyTouch®, SunTouch® Pool Control Systems and i-Link Firmware. Released: 3/4/22. Download the latest firmware versions: EasyTouch (2.190) ... to …Connecting an iPad to a printer can be a tricky process, but with the right troubleshooting tips and techniques, you can get your device up and running in no time. Here are some helpful tips on how to connect an iPad to a printer.. Kenmore gas dryer will not heat